qualité Clamp Type Flush Membrane Pressure Transmitter with 0.5% Accuracy for Medical Industry BP93420-IQT usine
<
qualité Clamp Type Flush Membrane Pressure Transmitter with 0.5% Accuracy for Medical Industry BP93420-IQT usine
qualité Clamp Type Flush Membrane Pressure Transmitter with 0.5% Accuracy for Medical Industry BP93420-IQT usine
qualité Clamp Type Flush Membrane Pressure Transmitter with 0.5% Accuracy for Medical Industry BP93420-IQT usine
qualité Clamp Type Flush Membrane Pressure Transmitter with 0.5% Accuracy for Medical Industry BP93420-IQT usine
qualité Clamp Type Flush Membrane Pressure Transmitter with 0.5% Accuracy for Medical Industry BP93420-IQT usine
>

Clamp Type Flush Membrane Pressure Transmitter with 0.5% Accuracy for Medical Industry BP93420-IQT

Certification: CE, RoHS
Minimum Order Quantity: 1
Price: 45

Product Details


Numéro de modèle.: BP93420-IQT Milieu de mesure: Liquide
Niveau de précision: 0,5% Plage de pression: - 100 Kpa... 0 Kpa ~ 35 Kpa... Je suis désolé.3.5 MPa
Indice IP: IP65 Type de pression: Pression de mesure, pression absolue, pression scellée
Matériau du boîtier: SS304 Réponse en fréquence: 2.4kHz
Poids: ~ 0,3 kg Matériau du diaphragme: 316L
Température de fonctionnement: -20ºC ~ 80ºC Température de stockage: -40ºC ~ 120ºC
Vibration: 10g, 55 Hz ~ 2KHz Résistance d&#39;isolation: 100mΩ 100VDC
Classification à l'épreuve des explosions: DB ex IIC T6 gigaoctet
Mettre en évidence

Clamp Type Flush Membrane Pressure Transmitter

,

0.5% Accuracy Pressure Sensor

,

Medical Industry BP93420-IQT

Product Description

BP93420-IQT Clamp Type Flush Membrane Pressure Transmitter
The BP93420-IQT pressure transmitter utilizes HT series silicon pressure-resistance isolation oil-filled core technology with a full metal flush diaphragm and direct welding with the process connection. This design ensures precise connections between the process connection and measuring diaphragm, preventing pressure hole blockage from crystallizing media.
Clamp Type Flush Membrane Pressure Transmitter with 0.5% Accuracy for Medical Industry BP93420-IQT 0 Clamp Type Flush Membrane Pressure Transmitter with 0.5% Accuracy for Medical Industry BP93420-IQT 1 Clamp Type Flush Membrane Pressure Transmitter with 0.5% Accuracy for Medical Industry BP93420-IQT 2
Key Features
  • Wide measurement range with various pressure interface options
  • Diverse output signal options for flexible integration
  • Adjustable zero and full-scale calibration
  • High accuracy with multiple sterile process connections
Applications
  • Measurement of non-corrosive gases and liquids with 316L compatibility
  • Medical, biopharmaceutical, and food hygiene industries for sterile processing
  • Paper and chemical industries, sewage level and beverage can pressure measurements
  • Hydraulic and pneumatic control systems
Performance Parameters
Measurement Range -100kPa…0kPa ~ 35kPa…3.5MPa
Pressure Type Gauge Pressure, Absolute Pressure, Sealed Pressure
Overload ≤ 1.5 times of the rated range
Accuracy @ 25ºC ±0.25% (Typical) ±0.5% (Maximum)
Repeatability ≤0.1%FS
Hysteresis ≤0.1%FS
Long-Term Stability ±0.1%F.S/Year(Typical) ±0.2%F.S/Year(Maximum)
Zero Point Temperature Drift ±0.02%F.S/ºC(≤100KPa) ±0.01%F.S/ºC(>100KPa)
Full Scale Temperature Drift ±0.02%F.S/ºC(≤100KPa) ±0.01%F.S/ºC(>100KPa)
Frequency Response 2.4Khz
Compensation Temperature 0-70ºC(≤10mpa,customizable)
Operating Temperature -20ºC~80ºC
Storage Temperature -40ºC~120ºC
Vibration 10g,55Hz ~ 2kHz
Housing Material 304,316L
Diaphragm Material 316L
Insulation Resistance 100MΩ 100VDC
Explosion-proof Rating Ex db IIC T6 Gb
Protection Rating IP65
O-Ring Seal Fluoro rubber
Weight ~0.3kg
Output Signal Specifications
Output Signal Supply Voltage Output Type
4~20mA 12~30VDC 2/3/4 wire
0~10/20mA 3 wire 0/1~5V, 0/1~10V, 0.5~4.5V
RS485 Communication Protocol 3.6~30V / Battery 4 wire
Clamp Type Flush Membrane Pressure Transmitter with 0.5% Accuracy for Medical Industry BP93420-IQT 3 Clamp Type Flush Membrane Pressure Transmitter with 0.5% Accuracy for Medical Industry BP93420-IQT 4 Clamp Type Flush Membrane Pressure Transmitter with 0.5% Accuracy for Medical Industry BP93420-IQT 5 Clamp Type Flush Membrane Pressure Transmitter with 0.5% Accuracy for Medical Industry BP93420-IQT 6
Ordering Information
Ordering Tips
  • Ensure medium compatibility with product contact parts
  • Explosion-proof type products do not include digital display heads
  • Transmitters with LCD/LED display require ≥20VDC power supply
  • Install lightning protection devices and ensure proper grounding
  • For temperatures below -20ºC, specify EPDM O-ring seal
  • Default cable length: 1.5m (polyethylene material)
  • Specify special requirements for vibration, impact, or interference
Order Guide
Code Outline Construction
IB General Pressure Transmitter
IX Display Pressure Transmitter
IE Shock-resistant Aviation Pressure Transmitter
IIC/III Industrial General/Display Pressure Transmitter
IF Moisture-proof Pressure Transmitter
IIE/IIIE General/Display Pressure Transmitter
IN Air Conditioning Dedicated Pressure Transmitter
IC High-temperature Pressure Transmitter
IQ1/IQ2 Large Diaphragm /High-temperature Pressure Transmitter
Frequently Asked Questions
What are the features of your pressure sensor transmitters?
High precision, durability, and excellent performance. Customization available.
Can I customize special specifications?
Yes, our engineers can tailor products to meet specific needs. We provide OEM and ODM service.
What is your production capacity?
Our manufacturing facilities can produce up to 30,000 pressure sensor transmitters per month, capable of meeting large-scale orders. Contact our sales team in advance for production and delivery scheduling.
What's the typical delivery period?
5-8 working days for standard models. Customized products may vary.
How are the products priced? Any discounts?
Competitive pricing with discounts for bulk orders or long-term partners.
What is the warranty of your products? And after-sales service?
24-month warranty after shipment. After-sales responds within 24 hours, with remote instruction by PC network always available.
Clamp Type Flush Membrane Pressure Transmitter with 0.5% Accuracy for Medical Industry BP93420-IQT 7 Clamp Type Flush Membrane Pressure Transmitter with 0.5% Accuracy for Medical Industry BP93420-IQT 8 Clamp Type Flush Membrane Pressure Transmitter with 0.5% Accuracy for Medical Industry BP93420-IQT 9 Clamp Type Flush Membrane Pressure Transmitter with 0.5% Accuracy for Medical Industry BP93420-IQT 10

Product Highlights

Transmetteur de pression à membrane affleurante de type pince BP93420-IQT. Précision élevée de 0,5 %, indice IP65 et diaphragme 316L pour les applications médicales/stériles. Sorties personnalisables, OEM disponibles, capacité de 2000 pièces/mois.

Related Products
qualité 19 mm Transmetteur de pression rempli d'huile Transmetteur de pression de silicium diffusé Épreuve d'huile d'eau usine

19 mm Transmetteur de pression rempli d'huile Transmetteur de pression de silicium diffusé Épreuve d'huile d'eau

Capteur de transmission de pression en silicium diffusé rempli d'huile pour les essais d'eau et d'huile Capteur de pression piézoresistif au silicium de 19 mm Introduction du capteur d'émetteur de pression Le HT19F fonctionne comme un capteur de pression piézorésistif en silicium, avec un noyau ...

qualité OEM Dépouilleur d'huile d'eau Transmetteur de pression du diaphragme Sensor de pression numérique de niveau de boisson usine

OEM Dépouilleur d'huile d'eau Transmetteur de pression du diaphragme Sensor de pression numérique de niveau de boisson

BP93420-IIIQT1 Huile d'eau OEM Collage pour boissons Capteur de pression du diaphragme BP93420-IIIQT1 Transmetteur de pression Introduction du détecteur de pression du diaphragme: BP93420-IIIQT1 capteur de pression à diaphragme est un capteur de pression analogique avec une structure à membrane ...

qualité BPHT24-III Capteur de pression numérique à diaphragme usine

BPHT24-III Capteur de pression numérique à diaphragme

Hengtong BPHT24-III Capteur de pression numérique du diaphragme Transmetteur de pression BPHT24-III Introduction d'un émetteur de détecteur de pression au diaphragme: L'émetteur de pression BPHT24-III est principalement utilisé dans la mesure de la pression de la machine anti-écaillage et anti...

qualité BPZK04-2 Pressostat électrique 24VDC 4-20mA Pressostat numérique Affichage LCD Pressostat électronique usine

BPZK04-2 Pressostat électrique 24VDC 4-20mA Pressostat numérique Affichage LCD Pressostat électronique

Pressostat électronique 24Vdc 4-20MA 2 points, pressostat numérique avec affichage LCD Pressostat électronique BPZK04-2 Introduction : Le pressostat électronique BPK-ZK04-2 est un ensemble de mesure de pression, d'affichage de contrôle et de sortie de transmission, le tout dans un produit de contr...

Request A Quote

Please use our online inquiry contact form below if you have any questions, our team will get back to you as soon as possible.

You can upload up to 5 files and Each file sized 10M max.